MiniBOOSTER Hydraulic Intensifier M-HC7-812B-10.3-1P02DA
- Payment by invoice possible
- Not currently in stock, contact us for factory lead times
- Payment by invoice possible
- In stock at factory, ready to ship in estimated 1-2 weeks, contact us for expedited options
- Del Rey is proud to be the exclusive distributor of Waagene products
- Payment by invoice possible
- Low quantities typically kept on hand; please contact us for availability at lead time
- Authorized MiniBOOSTER distributor & hydraulic excellence partner
Product Description
The miniBOOSTER Portable Intensifier System M-HC7 – 812B – 10.3 – 1P02DA is a rugged unit designed for demanding industrial applications. The M-HC7-DA can be used with any low-pressure, from 20 to 350 bar, and with a power source that provides a minimum flow of 2 l/min. Output pressure as high as 1,000 bar in both directions.
Reliability is a primary design consideration. The M-HC7-DA is equipped with a 12-micron filter and a visual filter condition indicator. Service life is extended and down-time avoided.
Portability and ease of operation
With a weight of only 14 kg and a convenient lifting handle, the M-HC7-DA can be easily carried to where it is needed. The M-HC7-DA operates from an existing low-pressure hydraulic supply. No additional utilities are required. All controls are incorporated into the unit and provide simple and reliable performance.
Time is money: The M-HC7-DA can deliver up to 40 l/min and is designed to ensure that system capacity is directed to your process until intensification is required. Cycle times are minimised. Many applications require that the unit provide exceptional accuracy. The M-HC7-DA is proven with two easy-to-read 4” diameter pressure gauges to permit accuracy to be controlled within a tolerance of 1%.
Additional information
Product Specifications
- Portable and easy to operate
- Reliable and simple performance
- Flexible design; several intensification factors
- Output pressurein both directions
- Multiple connection possibilities
- Extended service life
- Robust design
PIN: 20 – 350 bar
PH: Up to 2,000 bar maximum
Q: Up to 40 l/min
Weight: 14.0 kg/ 30.8 Lbs.
Function Diagram
Function Diagram M-HC7-812B-10.3-1P02DA
Dimension Drawing
Dimension Drawing M-HC7-812B-10.3-1P02DA
Connection Types
Connection | P / P1 / M1 / M2 / Z | T | Ha / Hb |
---|---|---|---|
M-HC7-812A-1___DA | 1/4″ BSPP | 3/8″ BSPP | 1/4″ BSPP – 120° cone |
Ordering an M-HC7-DA
Ordering example of an intensifier system M-HC7-DA for 1,000 bar with two (2) pressure-reducing valves, mounted with an HC7-FF with i = 10.3, DV incorporated and BSPP connections.
M-HC7-812B-1P02DA mounted with HC7 – 10.3 – B – FF
Attention notes!
Valve pre-settings are required, please specify when ordering the intensifier system.
Selection of intensifier system
Ordering code | Connection | Max. pressure | Weight |
---|---|---|---|
M-HC7-812A-1N02DA | Tube | 1000 bar | 14 kg |
M-HC7-812A-1O02DA | Tube | 1500 bar | 14 kg |
M-HC7-812A-1P02DA | Tube | 2000 bar | 14 kg |
Selection of HC7-FF intensification factor
Model | Intensification | Model version | Connection |
---|---|---|---|
HC7 | 4.0 | B | FF |
HC7 | 5.0 | B | FF |
HC7 | 6.6 | B | FF |
HC7 | 7.6 | B | FF |
HC7 | 9.0 | B | FF |
HC7 | 10.3 | B | FF |
HC7 | 13.0 | B | FF |
HC7 | 16.0 | B | FF |
HC7 | 20.0 | B | FF |
HC7 | 25.0 | B | FF |