MiniBOOSTER Hydraulic Intensifier HC2D-9.0-B-1
- Payment by invoice possible
- Not currently in stock, contact us for factory lead times
- Payment by invoice possible
- In stock at factory, ready to ship in estimated 1-2 weeks, contact us for expedited options
- Del Rey is proud to be the exclusive distributor of Waagene products
- Payment by invoice possible
- Low quantities typically kept on hand; please contact us for availability at lead time
- Authorized MiniBOOSTER distributor & hydraulic excellence partner
Product Description
The HC2D – 9.0 – B – 1 is a compact, high-flow dual-acting unit capable of delivering up to 2.2 l/min at high pressure. It autonomously adjusts to maintain pressure and compensates for oil consumption. Oil circulates through check valves and a directional valve to achieve maximum flow on the high-pressure side. Upon reaching the target pressure, valves close, and oscillating pump units sustain pressure, automatically adjusting for any drops. The unit efficiently stalls upon reaching the maximum pressure for optimal operation. Its versatility is highlighted by the option to customize high-pressure connections for various applications. Weighing just 3.4 kg/7.5 lbs, it seamlessly combines power with portability.
Additional information
Product specification
- HC2D versions: 13 different intensification factors.
- PIN: 20-207 bar.
- PH: 800 bar maximum.
- PRETURN: As low as possible (return pressure to tank).
- POUTLET: PH = (PIN – PRETURN) x intensification factor.
- Mounting: Inline tube.
- Weight: 3.4 kg/7.5 lbs.
Model versions
- A model = no dump valve.
- B model = with dump valve.
- G model = direct proportionally controlled.
Material certificate 9.0 on request
Flow Rates
Intensification Factor i | Max.Intensified Outlet flow i/min | Max. Inlet flow i/min |
---|---|---|
1.2 | 11.0 | 15.0 |
1.4 | 10.6 | 15.0 |
1.6 | 10.2 | 15.0 |
1.9 | 8.8 | 15.0 |
2.2 | 7.8 | 15.0 |
2.6 | 7.0 | 15.0 |
3.2 | 6.2 | 15.0 |
4.0 | 5.0 | 14.0 |
5.0 | 4.0 | 14.0 |
6.6 | 3.2 | 13.0 |
9.0 | 2.2 | 13.0 |
13.0 | 1.5 | 12.0 |
20.0 | 0.7 | 12.0 |
Function description
The basic operation is illustrated in the function diagram. Oil is fed through the directional valve CV to the IN port, flowing freely through the check valves 2x KV1, 2x KV2 and DV to the high-pressure side H. In this condition, maximum flow through the booster is achieved, giving a fast-forward function.
When pump pressure is reached on the high-pressure side H, valves KV1, KV2 and DV will close. The end pressure will be achieved by the oscillating pump units OP1 and OP2 by turns. The unit will automatically stall when end pressure on the high-pressure side H is reached. If a pressure drop on the high-pressure side exists due to consumption or leakage, the OP1 and OP2 units will automatically operate to maintain the end pressure. It is possible to change the high-pressure connection H to the opposite end of the booster.
Function diagram
Dimension
Dimension drawing HC2D-9.0-B-1
Connection Types
Connection | IN/R | H |
---|---|---|
1 | 1/4″ BSPP | 1/4″ BSPP |
Ordering an HC2D
Ordering example of an HC2D with I = 9.0, DV incorporated and BSPP connections: HC2D – 9.0 – B – 1
Attention note!
- Dynamic – low hysteresis: Ordering example of an HC2D with I = 9.0, RV incorporated and BSPP connections: HC2D – 9.0 – B – 1.
- Fail safe – high hysteresis: The RV valve opening ratio is to be determined on individual basis. Contact our technical support.
Model
- HC2D
Intensification,
- Select factor
- See flow rate table
Model Version.
- Select type
- A = without DV
- B = with DV
- G = with proportional valve
Connections
- Select thread
- 1 = BSPP