Product Description
The UPC3005 is a DIN-rail mountable serial line splitter with dual power inputs (15-30V DC, 2W each) and galvanic isolation. It features two prioritized inputs, six short-circuit protected outputs (five RS-422, three RS-232), and 1152000 Mbps speed. Installation uses screw terminals and supports up to 1.5 mm² cables.
Additional information
Product Specifications
Powersupply main | 15-30Vdc 2W |
Powersupply sec | 15-30Vdc 2W |
Input | A 1-20V, 0,5mA min, speed 1152000 Mbps. |
Outputs | 5 of RS-422, 50mA max, 3 of RS-232. |
Manufacturer | Overland |
All outputs are Short Circuit Protected
UPC3002 is a serial line splitter with two separate inputs and six outputs. Dual power input with autoswitch.
Input A and B are separated. InputA is prioritized.
If there is data on both input A and B, input A is used. Input B is used only if input A is out. The powersupply and both inputs are galvanic isolated from the outputs.
Installation notes
All connections to the serial splitter is done with plain screw terminals. The screw terminal will accept any cable up to 1,5 mm². For longer signal cable runs use shielded CAT5E cable or better (eg. Belden 9226723-04). The splitter is a “single listener/single talker” device, ie. each output should drive a single receiver, and the the input should be the sole listener on the input connection.
The splitter does not decode any NMEA sentences, and will pass all sentences and commands unchanged, regardless of message format, checksums, etc. The serial line splitter has true galvanic isolation between the power supply, inputs and outputs.
This means that inputs, outputs and power supply don’t have to be referenced to a common ground and this can be an advantage in larger installations. In installations where a common ground is preferred, it is permissible to connect these grounds together. In this case, mount a ground bar close to the serial line splitter and tie all ground connections to this. If the connections on the remote system has designators “A”, “B” and optionally “C”, use these
connections:
IEC 61162-1/IEC 61162-2
Signal Name |
UPC 3002/3005/5000P/6000
Connector Marking |
Description |
---|---|---|
A | + | Positive signal, will be negative with respect to – when idle. |
B | – | Negative signal, will be positive with respect to + when idle. |
C | Not used | Ground. Not used on UPC device. Do not connect to – The installer may opt to tie all external grounds together with a simple ground bar, see description above. |
In case any of the outputs are unused, the unconnected outputs should be terminated with a 120ohm resistor in order to comply with the EMC regulations. Cut the terminals of the resistor to the appropriate length and connect the resistor directly between the + and ? screw terminals.