MiniBOOSTER Hydraulic Intensifier HC2D-2.6-B-W

Category: Tag:

Product Description

The HC2D – 2.6 – B – W a dual-acting stainless steel 316L miniBOOSTER unit, delivers up to 11.0 l/min flow at the high-pressure end. It elevates supplied pressure to a higher outlet pressure while automatically compensating for oil consumption to sustain high pressure. Outlet pressure adjustment is achieved by varying the supplied pressure. Despite its high flow capability, it remains a compact unit, weighing 8.0 kg.

Additional information

Product Specifications

  • HC2W versions: 13 different intensification factors
  • PIN: 20-207 bar
  • PH: 800 bar maximum
  • PRETURN: As low as possible (return pressure to tank)
  • POUTLET: PH = (PIN – PRETURN) x intensification factor
  • Mounting: Inline tube
  • Weight: 8.0 kg

Model Versions:

  • A model = no dump valve
  • B model = with dump valve

Material certificate 3.1 on request

Flow Rate

Intensification Factor Max. Intensified Outlet Flow (l/min) Max. Inlet Flow (l/min)
1.2 11.0 15.0
1.4 10.6 15.0
1.6 10.2 15.0
1.9 8.8 15.0
2.2 7.8 15.0
2.6 7.0 15.0
3.2 6.2 15.0
4.0 5.0 14.0
5.0 4.0 14.0
6.6 3.2 13.0
9.0 2.2 13.0
13.0 1.5 12.0
20.0 0.7 12.0

Functions Desctiption

Oil flows through CV to IN port, via 2x KV1, 2x KV2, and DV to high-pressure side H, ensuring maximum booster flow. When pump pressure is reached, KV1, KV2, and DV close. OP1 and OP2 maintain end pressure alternately. Automatic stall at end pressure; OP1 and OP2 adjust for pressure drops. Optional H connection reversal.

Function Diagram

Function Diagram HC2D-2.6-B-W

Dimensions

Dimensions HC2D-2.6-B-W

High Pressure Adapters

High Pressure Adapters HC2D-2.6-B-W

Dynamic seals

Code Seal material Outlet pressure
HH H-PUR / H-PUR Max 800 bar HP
EE EPDM / EPDM Max 500 bar HP

Ordering an HC2DW

Ordering examples of an HC2W:
Ordering example of an HC2DW with i = 4.0, DV incorporated, BSPP connections and H-PUR dynamic seals:

HC2DW – 4.0 – B – 1HH for media < 5 cSt (mm2/s) tested in water HC2DW – 4.0 – B – 1SHH for media > 5 cSt (mm2/s) tested in hydraulic oil

Attention note!

High-pressure adapter is required, please specify ordering code – see high-pressure adapter table.
High-pressure adapters will be factory mounted.

Model

  • HC2DW

Intensification,i

  • Select factor
  • See flow rate table

Model Version.

  • Select type
  • A = without DV
  • B = with DV

Connections.

  • Select thread
  • 1 = BSPP, media < 5 cSt
  • 1S = BSPP, media > 5 cSt

Dynamic seals.

  • Select seal type
  • See dynamic seal table

Max. Tightening Torque BSPP

IN / R I1 / I2
1/4″ BSPP 1/8″ BSPP
with stainless steel washer 4.0 da/Nm 2.0 da/Nm